EG4 6000XP
Specs last updated . We don't track firmware versions.
Battery side
| Battery voltage | 48 V |
|---|---|
| Lowest battery voltage | 46.4 V |
| Highest battery voltage | 60 V |
| Max battery current | 140 A |
| Battery cable stud size | Not published |
AC output
| Continuous power | Not published |
|---|
Solar input
| Solar inputs (MPPT trackers) | 2 |
|---|---|
| Lowest working solar voltage | 120 V |
| Highest working solar voltage | 385 V |
| Solar voltage to start up | 100 V |
| Max solar voltage (Voc) | 480 V |
| Max current per solar input | 17 A |
| Max short-circuit current per solar input | 25 A |
| Max total solar power | 10000 W |
| Panel strings per solar input | 1 |
Battery communication
With closed-loop communication, the battery tells the inverter how to charge it. This inverter's maker documents these links:
EG4 hybrid closed loopBattery compatibility
- 7 Specs match
- 12 Needs manual setup
- 16 Partly checked
- 102 Not compatible
Show the 102 batteries that don't work
Where to buy
Sources
We pull these values from the maker's documents, and a person checks each one before it goes live. Store links never change a result.