What you'll set up yourself

  1. Enter the battery's charge settings on the inverter by hand, in the battery settings described in the inverter's manual.
    • Max charge current: no more than 37.5 A per battery, from the battery's spec sheet.
    • Charge voltage, float voltage, and low-voltage cutoff: from the SimpliPhi Power PHI-3.8-48-60 manual.

Published limits, side by side

Spec MidNite Solar Rosie MNROSIE7048RE SimpliPhi Power PHI-3.8-48-60
Voltage 48 V accepts 40–65 V 51.2 V
Current Max battery current 210 A Max charge 37.5 A Max output 37.5 A Peak output 80 A
Communication MidNite Rosie CAN Open loop (no comms)
Cable connection Stud size 5/16 in Terminal 3/8 IN (10 mm)

Values come from each maker's documents. "Not published" means the maker doesn't state it.

Confirm with the makers before you buy

This result checks two things: the battery's voltage suits the inverter, and the inverter maker lists this battery for closed-loop communication (the battery tells the inverter how to charge it). It doesn't check current limits, charge settings, firmware, cable sizes, or safe installation. Confirm those with both makers before you buy.

Sources

This result comes from the documents below. We haven't yet found an outside source that confirms it, such as a forum report or a video of a real install.

Where to buy

MidNite Solar Rosie MNROSIE7048RE

  • No store links yet. The maker's site is below.
  • MidNite Solar (maker)

SimpliPhi Power PHI-3.8-48-60

Spot a mistake? Email errata@offgridstacks.com with this page's link.