Renogy RIV4835CSH1S + Fortress Power eFlex MAX 5.4

Checked automatically against spec sheets. Not yet confirmed in a real install. Last checked 2026-10-12. We don't track firmware versions.

What you'll set up yourself

  1. Enter the battery's charge settings on the inverter by hand, in the battery settings described in the inverter's manual.
    • Max charge current: no more than 100 A per battery, from the battery's spec sheet.
    • Charge voltage, float voltage, and low-voltage cutoff: from the Fortress Power eFlex MAX 5.4 manual.

Published limits, side by side

Spec Renogy RIV4835CSH1S Fortress Power eFlex MAX 5.4
Voltage 48 V accepts 40–60 V 51.2 V
Current Max battery current 85 A Max charge 100 A Max output 100 A Peak output 130 A
Communication Open loop (no comms) Sol-Ark closed loopGrowatt SPF/SPE closed loopOpen loop (no comms)
Cable connection Stud size 5/16" Terminal M8

Values come from each maker's documents. "Not published" means the maker doesn't state it.

Confirm with the makers before you buy

This result checks two things: the battery's voltage suits the inverter, and the inverter maker lists this battery for closed-loop communication (the battery tells the inverter how to charge it). It doesn't check current limits, charge settings, firmware, cable sizes, or safe installation. Confirm those with both makers before you buy.

Sources

This result comes from the documents below. We haven't yet found an outside source that confirms it, such as a forum report or a video of a real install.

Where to buy

Renogy RIV4835CSH1S

  • No store links yet. The maker's site is below.
  • Renogy (maker)

Fortress Power eFlex MAX 5.4

  • No store links yet. The maker's site is below.
  • Fortress Power (maker)

Spot a mistake? Email errata@offgridstacks.com with this page's link.