Not compatible

Schneider Electric XW Pro 6848 NA + BigBattery 24V Eagle 2 64Ah

Checked automatically against spec sheets. Not yet confirmed in a real install. Last checked 2026-10-14. We don't track firmware versions.

What you'll set up yourself

  1. Closed-loop communication needs an extra part: Conext Gateway, InsightHome or InsightFacility; single XW Pro without Conext MPPT controllers.

Published limits, side by side

Spec Schneider Electric XW Pro 6848 NA BigBattery 24V Eagle 2 64Ah
Voltage 48 V accepts 40–64 V 25.6 V
Current Max battery current 180 A Max charge 64 A Max output 100 A Peak output 200 A
Communication Schneider XW Pro BMS None listed
Cable connection Stud size 3/8-16 bolt Terminal M8 terminal

Values come from each maker's documents. "Not published" means the maker doesn't state it.

Confirm with the makers before you buy

This result checks two things: the battery's voltage suits the inverter, and the inverter maker lists this battery for closed-loop communication (the battery tells the inverter how to charge it). It doesn't check current limits, charge settings, firmware, cable sizes, or safe installation. Confirm those with both makers before you buy.

Sources

This result comes from the documents below. We haven't yet found an outside source that confirms it, such as a forum report or a video of a real install.

Where to buy

Schneider Electric XW Pro 6848 NA

BigBattery 24V Eagle 2 64Ah

  • No store links yet. The maker's site is below.
  • BigBattery (maker)

Spot a mistake? Email errata@offgridstacks.com with this page's link.