Needs manual setup

Schneider Electric XW Pro 6848 NA + PYTES V5

Checked automatically against spec sheets. Not yet confirmed in a real install. Last checked 2026-10-12. We don't track firmware versions.

What you'll set up yourself

  1. Enter the battery's charge settings on the inverter by hand, in the battery settings described in the inverter's manual.
    • Max charge current: no more than 100 A per battery, from the battery's spec sheet.
    • Charge voltage, float voltage, and low-voltage cutoff: from the PYTES V5 manual.
  2. Closed-loop communication needs an extra part: Conext Gateway, InsightHome or InsightFacility; single XW Pro without Conext MPPT controllers.

Published limits, side by side

Spec Schneider Electric XW Pro 6848 NA PYTES V5
Voltage 48 V accepts 40–64 V 51.2 V
Current Max battery current 180 A Max charge 100 A Max output 100 A Peak output 180 A
Communication Schneider XW Pro BMS EG4 hybrid closed loopVictron BMS-CanSol-Ark closed loopGrowatt SPF/SPE closed loopOpen loop (no comms)
Cable connection Stud size 3/8-16 bolt Terminal M6 bolt

Values come from each maker's documents. "Not published" means the maker doesn't state it.

Confirm with the makers before you buy

This result checks two things: the battery's voltage suits the inverter, and the inverter maker lists this battery for closed-loop communication (the battery tells the inverter how to charge it). It doesn't check current limits, charge settings, firmware, cable sizes, or safe installation. Confirm those with both makers before you buy.