Partly checked
Victron Energy MultiPlus 48/2000/25-50 120V + EG4 WallMount Indoor 314Ah
- Voltage matches: the 51.2 V battery suits this 48 V inverter.
- Can't check battery communication yet: the inverter's communication links aren't on file.
Checked automatically against spec sheets. Not yet confirmed in a real install. Last checked 2026-10-28. We don't track firmware versions.
Size the battery cable and fuse for this pair in the build tool, from your run length.
Published limits, side by side
| Spec | Victron Energy MultiPlus 48/2000/25-50 120V | EG4 WallMount Indoor 314Ah |
|---|---|---|
| Voltage | 48 V accepts 38–66 V | 51.2 V |
| Current | Max battery current Not published | Max charge 157 A Max output 200 A |
| Communication | None listed | EG4 hybrid closed loopEG4 EHV closed loopGrowatt SPF/SPE closed loop |
| Cable connection | Stud size M8 | Terminal Degson quick connector/screw terminal |
Values come from each maker's documents. "Not published" means the maker doesn't state it.
Confirm with the makers before you buy
- Each product's current limits. One or both aren't published, so ask both makers.
- Which firmware versions support this pairing. We don't track firmware.
- That your cable lugs fit the inverter's battery studs (M8) and the battery's terminals (Degson quick connector/screw terminal).
- How to install both safely, from each maker's manual and your local code.
This result checks two things: the battery's voltage suits the inverter, and the inverter maker lists this battery for closed-loop communication (the battery tells the inverter how to charge it). It doesn't check current limits, charge settings, firmware, cable sizes, or safe installation. Confirm those with both makers before you buy.
Sources
This result comes from the documents below. We haven't yet found an outside source that confirms it, such as a forum report or a video of a real install.
Where to buy
Victron Energy MultiPlus 48/2000/25-50 120V
- Current Connected
- Victron Energy (maker)
EG4 WallMount Indoor 314Ah
Spot a mistake? Email errata@offgridstacks.com with this page's link.