Not compatible

Schneider Electric SW 4048 120/240 + Battle Born Batteries BBGC3

Checked automatically against spec sheets. Not yet confirmed in a real install. Last checked 2026-10-12. We don't track firmware versions.

Published limits, side by side

Spec Schneider Electric SW 4048 120/240 Battle Born Batteries BBGC3
Voltage 48 V accepts 40–68 V 12 V
Current Max battery current 110 A Max charge 135 A Max output 300 A Peak output 500 A
Communication Open loop (no comms) Open loop (no comms)
Cable connection Stud size 3/8 in Terminal .25" Brass

Values come from each maker's documents. "Not published" means the maker doesn't state it.

Confirm with the makers before you buy

This result checks two things: the battery's voltage suits the inverter, and the inverter maker lists this battery for closed-loop communication (the battery tells the inverter how to charge it). It doesn't check current limits, charge settings, firmware, cable sizes, or safe installation. Confirm those with both makers before you buy.

Sources

This result comes from the documents below. We haven't yet found an outside source that confirms it, such as a forum report or a video of a real install.

Where to buy

Schneider Electric SW 4048 120/240

Battle Born Batteries BBGC3

Spot a mistake? Email errata@offgridstacks.com with this page's link.