Needs manual setup

Schneider Electric SW 4048 120/240 + SOK Battery SK48V100N

Checked automatically against spec sheets. Not yet confirmed in a real install. Last checked 2026-10-12. We don't track firmware versions.

What you'll set up yourself

  1. Ask SOK Battery whether this battery can run without communication. Their documents don't say.
  2. Enter the battery's charge settings on the inverter by hand, in the battery settings described in the inverter's manual.
    • Max charge current: no more than 100 A per battery, from the battery's spec sheet.
    • Charge voltage, float voltage, and low-voltage cutoff: from the SOK Battery SK48V100N manual.

Published limits, side by side

Spec Schneider Electric SW 4048 120/240 SOK Battery SK48V100N
Voltage 48 V accepts 40–68 V 51.2 V
Current Max battery current 110 A Max charge 100 A Max output 100 A Peak output 120 A
Communication Open loop (no comms) Growatt SPF/SPE closed loop
Cable connection Stud size 3/8 in Terminal M8

Values come from each maker's documents. "Not published" means the maker doesn't state it.

Confirm with the makers before you buy

This result checks two things: the battery's voltage suits the inverter, and the inverter maker lists this battery for closed-loop communication (the battery tells the inverter how to charge it). It doesn't check current limits, charge settings, firmware, cable sizes, or safe installation. Confirm those with both makers before you buy.